09276643398 5446087
Metro Manila
Gas Shut Off Devices Commercial Gas Lines,
We are one of the largest free online selling communities with thousands of active sellers.
Do you have something to sell? Your next sale might be just a few clicks away.
Based from 899 member feedbacks. We value your suggestions and use it.
Gas Shut Off Devices Commercial Gas Lines
Globe: 09276643398
Smart: 09195779955
PLDT: 544-6087
Email: [email protected]
Gas Shut Off Devices - 5,000 Php ( Item Only )
Gas Shut Off Devices Commercial Gas Lines
TERMS OF PAYMENT:
ESTIMATED COMPLETION:
WARRANTY TERMS:
50% Down Payment: Balance Upon Completion of Installation
One ( 1 ) Working Days
One ( 1 ) Year Warranty
PROFORMA INVOICE
QTY
UNIT
REQUIRMENT
UNIT COST
TOTAL COST
1
pc
Control Panel Hankok brand
4,000.00
4,000.00
1
pc
Gas leak Detector
4,000.00
4,000.00
1
pc
Automatic Shut-off Valve
4,000.00
4,000.00
1
lot
Electrical assorted fittings
3,000.00
3,000.00
1
lot
Installation Cost, Testing & Turn-Over
5,000.00
5,000.00
TOTAL AMOUNT:
20,000.00
Gas Line Labor and Installation
Price are only applied in Metro Manila Area ( Alabang - Muntinlupa )
Residential Gas Line - 25,000
Condo Residence - 25,000
Laundry Gas Line - 35,000
Commercial Gas Line ( Outside Tank ) 35,000
Commercial Gas Line ( Inside Mall) 45,000
Manually turning off the gas service shutoff valve is the most common method to stop the flow of gas serving a building, or part of a building, in case of an emergency. Gas service shutoff valves are installed by PG&E at all gas meter locations or outside locations if the meter is not accessible from the outside.
Keep a 12 to 15-inch adjustable pipe wrench or Crescent-type wrench available to close the valve in case of an emergency. Earthquake wrenches with fixed openings may not fit a particular valve, so an adjustable type is best. To minimize the possibility of unauthorized operation of the valve, wrenches should be located nearby, but not at the gas meter location.
Shut off the gas service shutoff valve only if you smell gas, hear gas escaping, see a broken gas line, or if you suspect a gas leak.
To shut off the gas, rotate the valve a quarter turn in either direction; the valve is closed when the tang (the part you put the wrench on) is crosswise to the pipe.
In addition, most gas appliances have a gas shutoff valve located near the appliance that lets you turn off the gas to that appliance only. Know which of your appliances use gas, and where the appliance gas shutoff valves are located. In some cases, turning off the gas at the appliances shutoff valve will suffice.
Automatic Gas Shutoff Devices
Some cities and counties have regulations that require the installation of automatic gas shutoff devices, which may include excess flow gas shutoff valves and/or earthquake actuated gas shutoff valves. Regulations vary, but generally apply to new building construction, or significant alterations or additions to existing buildings. Check with your local city or county agency to see if regulations apply in your area.
If a customer installs an excess flow gas shutoff valve or earthquake actuated gas shutoff valve, it should be one that is certified by the State of California and it should be installed by a licensed plumbing contractor in accordance to the manufacturers instructions. PG&E does not install or service seismic actuated or excess flow gas shutoff valves, or recommend specific contractors for customer applications.
The State of California is required to approve all excess flow gas shutoff valves and earthquake actuated gas shutoff valves used in the State of California. The State of California is required to approve all excess flow gas shutoff valves and earthquake actuated gas shutoff valves used in the State of California. A list of approved valves is available on the DSA Gas Shut-off Valves Certification Program webpage.
Excess flow gas shutoff valves and earthquake actuated gas shutoff valves must be installed on the buildings gas houseline piping (the gas pipe connecting your appliances to the gas meter) downstream of the utility point of delivery; i.e. after the PG&E gas shutoff valve, pressure regulator (if installed), meter(s), and the service tee. No attachments or connections of any kind are allowed on utility facilities prior to the point where the service tee connects to the gas houseline piping. Once installed, the valve must not obstruct the operation or serviceability of PG&E’s piping, gas service shutoff valve, gas meter or gas pressure regulating equipment.
In the event that a gas service shutoff valve or an automatic gas shutoff device is closed, there may be a considerable delay before PG&E can turn your service on, but do not turn it on yourself. PG&E or another qualified professional should perform a safety check, restore gas service, and relight any appliance pilots, even if the closure was not caused by an earthquake.
Globe: 09276643398
Smart: 09195779955
PLDT: 544-6087
Email: [email protected]
If you have requirements please dont hesitate to inquire. Well be very glad to assist you.
This seller has been a member since: May. 19, 2015
Member Location:
Total Classifieds: 7
Why seller feedback is important?
Transact with most credible & reputable sellers
Know the seller you are going to deal with
Claim warranty long after purchasing the item
Warn you and other buyers against scams
Motivates sellers to provide good service